Enhancements
Release Y.11.16 Enhancements
To continue the example in figure 5, suppose that you wanted the switch to:
Send updates every 10 minutes on in-progress accounting sessions.
Block accounting for unknown users (no username).
Figure 7. Example of Optional Accounting Update Period and Accounting Suppression on Unknown User
Syntax: [no] aaa accounting update periodic < 1 - 525600 >
Sets the accounting update period for all accounting ses-
sions on the switch. (The no form disables the update
function and resets the value to zero.) (Default: zero; dis-
abled)
Syntax: [no] aaa accounting suppress null-username
Disables accounting for unknown users having no user-
name. (Default: suppression disabled)
ProCurve(config)# aaa accounting update periodic 10
ProCurve(config)# aaa accounting suppress null-username
ProCurve(config)# show accounting
Status and Counters - Accounting Information
Interval(min) : 10
Suppress Empty User : Yes
Sessions Identification : Common
Type | Method Mode
-------- + ------ --------------
Network | None
Exec | Radius Start-Stop
System | Radius Stop-Only
Commands | Radius Interim-Update
Update Period
Suppress Unknown User
Vista de pagina 38